menu

Hips

Hexagonal (120°) tower with handed arris hip tiles9.1-hexagonal--120--tower_250x202

At each hip left and right-handed arris hip tiles are used in alternate courses to maintain a broken bond to each side of the hip.

 

 

 

 

 

Octagonal (135°) tower with large & small hip tiles9.2-octagonal--135--tower_250x205

At each hip large and small arris hip tiles are used in alternate courses to maintain a broken bond to each side of the hip.

 

 

 

 

 

Octagonal (135°) tower with mitred hips9.3-Octagonal--135--tower-m_250x201

Tiles and tile-and-a-half tiles are cut and fixed to form a straight, weathertight, close mitred junction at the hip.

The mitred tiles are interleaved with metal soakers, extending a minimum 100mm to each side of hip. The soakers are secured by turning down over heads of mitred tiles.

Extreme care is needed to achieve a neat finish at the hip. Where possible it is advisable to use specially made arris hip tiles to suit the particular roof pitch instead.

 

Photograph shows an example of an octagonal tower9.31-Octagonal-hip-image_250x236

(Photograph courtesy of Marley Ltd)

 

 

 

 

 

 

 

Mitred hips9.4-mitred-hips_250x258

Lay courses of underlay over hip with overlaps of not less than 150mm.

Cut tile-and-a-half tiles and fix to form a straight, weathertight, close mitred junction.

Interleave mitred tiles with metal soakers, extending a minimum 100mm to each side of hip. Fix soakers by turning down over heads of mitred tiles.

Extreme care is needed to achieve a neat finish at the hip. Where possible it is advisable to use either bonnet hip tiles or specify specially made arris hip tiles to suit the particular roof pitch instead.

 

9.4-mitred-hip-image_250x228Photograph shows an example of a hexagonal tower

(Photograph courtesy of Sandtoft)

 

 

 

 

 

4-way hip cap9.5-4-way-hip-cap_249x166

Where four mitred, bonnet or arris hips terminate without a ridge line, a purpose-made cap or finial can be used.

Because hip caps and finials are pitch specific please contact the tile manufacturer with roof details.

Decorative finials can be made to order.

Hips with unequal roof pitches9.6-hips-with-unequal-roof-_250x251

If it is required to continue the tile courses in line around the hip line, and the roof pitches at each face are unequal, it will be necessary to set out the tile batten gauge on the lesser pitch first. Then, the battens on the steeper pitch can be fixed in line with the first battens. This will necessitate having a shorter gauge on the steeper side and should therefore be checked before installation to ensure it is suitable for the size of the tile being used.

 

 

 

This sectional detail shows the battens on the steeper pitch set out at a lesser gauge to line up with the battens on the lesser pitch.9.6-hips-with-unequal-roof1_250x160